Every water-heater plan keeps the tank at or above a floor, and runs a cycle that heats the tank hotter for an hour every couple of days:

  • Floor. The plan never schedules the tank below this temperature, day or night. Default 120°F.
  • Cycle. Every two days by default, the plan heats the tank to 140°F and holds it there for 60 minutes, in whichever upcoming slots cost the least. The 140°F figure and the hold time both come from your settings, not from a fixed rule.

Defaults: floor 120°F, cycle temperature 140°F, hold 60 minutes, every 2 days.

When a tank temperature sensor is configured, the plan also reports whether the last cycle actually reached temperature. That check does not change the schedule — see What it cannot do for why.

  • A thermostat set at or above the cycle temperature. Hungry Machines switches the heating element; your tank’s own thermostat decides how hot the water can get. If the dial sits at 125°F, a 140°F cycle never reaches 140°F, and the schedule has no way to tell.
  • A mixing valve at the tank, or anti-scald valves at each tap, before the stored water runs this hot. Water at 140°F can scald in seconds.

Open the water heater’s Edit constraints. Five fields cover this:

Field Label in the editor Range Default
floor_temp_f Never plan below 60–160°F 120°F
sanitize_enabled Heat the tank on a schedule on / off on
sanitize_temp_f Cycle temperature 140–160°F 140°F
sanitize_hold_minutes Hold for (minutes) 30–180 60
sanitize_interval_days Every (days) 1–14 2

Turning off Heat the tank on a schedule stops the cycle; the floor still applies. Setting the floor itself to 140°F keeps the tank there at all times instead of cycling — see below.

Hungry Machines heats the tank and, when a sensor is fitted, reports whether it reached temperature. It cannot see the bottom of the tank, where water sits coolest and stored the longest. One study of 178 homes found bacteria in 37–39% of electric water heaters, none in oil or gas ones (Alary and Joly, 1991).

Health agencies advise storing hot water at 140°F at all times, not on a cycle. The settings here allow that: set the floor to 140°F. We offer the lower-cost cycle as a choice, not as the agencies’ recommendation.

Sources:

Register the pump as a pool_pump appliance, pointed at the switch that turns it on and off. Two settings control the plan:

  • Run time per day (hours) — how long the pump needs to run each day. Default 8.
  • Allowed from / Allowed until — the window the pump is allowed to run in. Default 08:00 to 20:00.

The plan turns the pump on in the cheapest slots inside that window until the run time is met, and never outside it. The dashboard card shows the same shape as a charging appliance: 0% at the start of the day, 100% once the run time is reached.

Register the tub as a hot_tub appliance, pointed at its climate or water-heater entity. The plan works from soak times rather than a flat temperature:

  • Ready temperature — the temperature the tub holds through each soak window. Default 102°F.
  • Between soaks, no lower than — the temperature the tub may drift down to outside those windows. Default 95°F.
  • Soak windows — up to four, each with a start time, an end time, and which days it applies to.

Outside your soak windows, the tub is allowed to drift down toward the eco temperature; the plan reheats it in the cheapest slots so it’s back at the ready temperature by the time each window starts. It is never switched off, and its mode is never changed — only its target temperature moves. If a soak starts early in the morning, the plan raises the previous evening’s minimum so there’s time to reheat before then.

A small heater takes hours to bring a tub back up, not minutes. Setting soak windows close together, or a wide gap between the ready and eco temperatures, leaves less room to find a cheap slot before the next soak.